AQA GCSE Combined Science: Trilogy · Virtual Lab

Chromatography

Required practical 12 · 5.8 Chemistry: Chemical analysis · Spec 5.8.1.3
Aim: Use paper chromatography to separate the dyes in an unknown ink, identify them and work out their Rf values.

Do it in the virtual lab: choose the kit, plan the method, take your own readings, then use your results and answer exam questions. Every run gives new readings.

Revise this practical

Equipment

Show the kit
  • Chromato­graphy paper: The stationary phase the dyes move up.
  • Pencil: For the start line and the solvent front: graphite does not dissolve and move.
  • Ruler: Measures how far each spot and the solvent moved.
  • Beaker with a lid: Holds the solvent; the lid stops it evaporating.
  • Capillary tube: Puts small, neat spots of each ink on the line.
  • Water (the solvent): The mobile phase that carries the dyes.

Method

Show the method
  1. Draw a pencil line about 2 cm from the bottom of the chromatography paper.
  2. Put a small spot of the unknown ink and each known dye on the line, spaced apart.
  3. Pour water into the beaker to a depth of about 1 cm.
  4. Hang the paper in the beaker so it dips into the water below the line, and put the lid on.
  5. Take the paper out when the solvent is near the top, and mark the solvent front in pencil.
  6. Measure how far each spot and the solvent moved, and work out the Rf values.

The variables

  1. Why must the start line be above the water?

    Show answer

    Otherwise the dyes dissolve into the water in the beaker

    The dyes must be carried up the paper by the solvent.

  2. What is the mobile phase?

    Show answer

    The water (solvent)

    The paper is the stationary phase.

  3. Why put a lid on the beaker?

    Show answer

    To stop the solvent evaporating from the paper

    The air inside stays full of solvent vapour.

Remember

  • Pencil start line above the solvent; small spots; lid on the beaker.
  • Rf = distance moved by substance ÷ distance moved by solvent (always less than 1).
  • Pure substance: one spot. Mixture: more than one spot.
  • Same Rf in the same solvent = same substance.
  • Mobile phase: the solvent. Stationary phase: the paper.

Exam-style questions

  1. How does a chromatogram show a pure substance?

    Show answer

    It gives one spot

    A pure substance has the same Rf value in a given solvent every time.

  2. A spot stayed on the start line. What does that show?

    Show answer

    That substance is insoluble in this solvent

    Try a different solvent to make it move.

  3. Which is the formula for Rf?

    Show answer

    distance moved by substance ÷ distance moved by solvent

    Rf is always less than 1.

Play next

Share with your class

Teachers: send this page to your students. It is free and needs no sign-up.