AQA A-level Environmental Science · Virtual Lab

Woodland and grassland microclimate

Required technique ST1 · 3.1 The living environment · Spec 3.1.3, Me5
Aim: Measure temperature, humidity and light intensity through a day in a wood and in open grassland, and compare their microclimates.

Do it in the virtual lab: choose the kit, plan the method, take your own readings, then use your results and answer exam questions. Every run gives new readings.

Revise this practical

Equipment

Show the kit
  • Digital thermometer: Measures air temperature.
  • Hygrometer: Measures relative humidity, the % of water vapour the air holds compared with the most it could hold.
  • Light meter: Measures light intensity in lux.
  • Watch: So the readings at both sites are taken at the same times.
  • Recording sheet: Record each reading with the time.

Method

Show the method
  1. Choose a site inside the wood and one in the open grassland next to it, on the same slope and aspect.
  2. Let the instruments settle at the site for a minute before reading them.
  3. Measure temperature and humidity at the same height (1 m) above the ground.
  4. Measure light intensity with the sensor pointing straight up, at the same height.
  5. Take readings at both sites at the same times: every 3 hours from 06:00 to 18:00.
  6. Repeat on several days with similar weather and compare the daily ranges.

The variables

  1. Why take readings at both sites at the same times (Me5)?

    Show answer

    Temperature, humidity and light change through the day (diurnal changes)

    Sample timing matters when a variable changes with time of day, weather or season.

  2. What is the independent variable?

    Show answer

    The habitat (woodland or open grassland)

    You compare two habitats.

  3. Why let the instruments settle first?

    Show answer

    They need time to reach the conditions at the site

    A thermometer carried from a warm pocket gives a false reading at first.

Remember

  • ST1 abiotic factors: light (lux meter), temperature, humidity (hygrometer), wind velocity (anemometer), turbidity, ion concentration, pH.
  • Sample timing (Me5): take readings at the same times when variables change through the day, with the weather or the seasons.
  • Let instruments settle; measure at the same height; sensor pointing up for light.
  • Woodland canopy gives a smaller range of temperature and humidity, and much lower light at ground level.

Exam-style questions

  1. Why is humidity usually highest early in the morning?

    Show answer

    The air is coolest, so the same water vapour is a higher % of what the air can hold

    Warm air can hold more water vapour, so relative humidity falls as the air warms.

  2. Which sampling technique group (ST1) do these measurements belong to?

    Show answer

    Measurement of abiotic factors

    ST1: light, temperature, wind velocity, humidity, turbidity, ion concentrations and pH.

  3. Why should both sites have the same slope and aspect?

    Show answer

    Slope and aspect change how much sunlight a site gets, so they would be confounding variables

    Only the habitat should differ between the two sites.

Play next

Share with your class

Teachers: send this page to your students. It is free and needs no sign-up.