AQA A-level Environmental Science · Virtual Lab

Biochemical oxygen demand (BOD)

Extra practical · 3.4 Pollution · Spec 3.4.3.2
Aim: Measure the BOD of river water at different distances below a sewage works to show how organic pollution and recovery change along a river.

Do it in the virtual lab: choose the kit, plan the method, take your own readings, then use your results and answer exam questions. Every run gives new readings.

Revise this practical

Equipment

Show the kit
  • Dark glass BOD bottles: Filled to the top and kept in the dark so no oxygen is made by photosynthesis.
  • Dissolved oxygen meter: Measures the oxygen in the water on day 0 and day 5.
  • Incubator at 20 °C: Keeps every sample at the same temperature for 5 days.
  • Sample bottles: Collect water from each site.

Method

Show the method
  1. Collect water from each site in two dark bottles, filled to the top with no air bubbles.
  2. Measure the dissolved oxygen in one bottle straight away (day 0).
  3. Seal the second bottle so no air can get in.
  4. Keep it in the dark at 20 °C for 5 days.
  5. Measure the dissolved oxygen in the second bottle (day 5).
  6. BOD = oxygen on day 0 − oxygen on day 5.

The variables

  1. What does BOD measure?

    Show answer

    How much oxygen microorganisms use to break down organic matter in the water

    High BOD = lots of organic pollution.

  2. Why keep the bottles in the dark?

    Show answer

    To stop algae photosynthesising and adding oxygen

    Then any fall in oxygen is from respiration by decomposers.

  3. Why incubate at 20 °C?

    Show answer

    Temperature changes the rate of decomposition, so it must be the same for every sample

    A standard method allows comparison.

Remember

  • BOD = dissolved oxygen on day 0 − after 5 days in the dark at 20 °C (mg/dm³).
  • Dark bottles, full with no air bubbles, sealed; same temperature for all samples.
  • High BOD = much organic pollution; BOD falls downstream as decomposition and dilution clean the river.
  • Sewage treatment uses microorganisms to cut BOD before discharge.

Exam-style questions

  1. Which BOD shows clean river water?

    Show answer

    Under about 3 mg/dm³

    Untreated sewage can have a BOD of several hundred mg/dm³.

  2. Why does organic pollution lower oxygen in a river?

    Show answer

    Aerobic bacteria multiply and use oxygen to respire as they decompose it

    The fall in oxygen kills sensitive animals such as stonefly nymphs and fish.

  3. How does a sewage works reduce BOD before discharge?

    Show answer

    Bacteria in aerated tanks (activated sludge) or trickling filters break down the organic matter

    Primary settling removes solids; secondary treatment uses microorganisms.

Play next

Share with your class

Teachers: send this page to your students. It is free and needs no sign-up.